Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Heliyon ; 10(9): e29672, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38699042

RESUMO

Introduction: Loss of cutaneous protective sensation and high plantar pressures increase the risk for diabetic foot patients. Trauma and ulceration are imminent threats, making assessment and monitoring essential. This systematic review aims to identify systems and technologies for measuring in-shoe plantar pressures, focusing on the at-risk diabetic foot population. Methods: A systematic search was conducted across four electronic databases (Scopus, Web of Science, PubMed, Oxford Journals) using PRISMA methodology, covering articles published in English from 1979 to 2024. Only studies addressing systems or sensors exclusively measuring plantar pressures inside the shoe were included. Results: A total of 87 studies using commercially available devices and 45 articles proposing new systems or sensors were reviewed. The prevailing market offerings consist mainly of instrumented insoles. Emerging technologies under development often feature configurations with four, six or eight resistive sensors strategically placed within removable insoles. Despite some variability due to the inherent heterogeneity of human gait, these devices assess plantar pressure, although they present significant differences between them in measurement results. Individuals with diabetic foot conditions appears exhibit elevated plantar pressures, with reported peak pressures reaching approximately 1000 kPa. The results also showed significant differences between the diabetic and non-diabetic groups. Conclusion: Instrumented insoles, particularly those incorporating resistive sensor technology, dominate the field. Systems employing eight sensors at critical locations represent a pragmatic approach, although market options extend to systems with up to 960 sensors. Differences between devices can be a critical factor in measurement and highlights the importance of individualized patient assessment using consistent measurement devices.

2.
Heliyon ; 10(4): e26161, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38390156

RESUMO

Background: The development of ulcers in the plantar region of the diabetic foot originates mainly from sites subjected to high pressure. The monitoring of these events using maximum allowable pressure thresholds is a fundamental procedure in the prevention of ulceration and its recurrence. Objective: The aim of this review was to identify data in the literature that reveal an objective threshold of plantar pressure in the diabetic foot, where pressure is classified as promoting ulceration. The aim is not to determine the best and only pressure threshold for ulceration, but rather to clarify the threshold values most used in clinical practice and research, also considering the devices used and possible applications for offloading plantar pressure. Design: A systematic review. Methods: The search was performed in three electronic databases, by the PRISMA methodology, for studies that used a pressure threshold to minimize the risk of ulceration in the diabetic foot. The selected studies were subjected to eligibility criteria. Results: Twenty-six studies were included in this review. Seven thresholds were identified, five of which are intended for the inside of the shoe: a threshold of average peak pressure of 200 kPa; 25 % and 40-80 % reduction from initial baseline pressure; 32-35 mm Hg for a capillary perfusion pressure; and a matrix of thresholds based on patient risk, shoe size and foot region. Two other thresholds are intended for the barefoot, 450 and 750 kPa. The threshold of 200 kPa of pressure inside the shoe is the most agreed upon among the studies. Regarding the prevention of ulceration and its recurrence, the efficacy of the proposed threshold matrix and the threshold of reducing baseline pressure by 40-80 % has not yet been evaluated, and the evidence for the remaining thresholds still needs further studies. Conclusions: Some heterogeneity was found in the studies, especially regarding the measurement systems used, the number of regions of interest and the number of steps to be considered for the threshold. Even so, this review reveals the way forward to obtain a threshold indicative of an effective steppingstone in the prevention of diabetic foot ulcer.

3.
J Mot Behav ; 56(2): 195-210, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37990958

RESUMO

This study aims to identify differences between participants with and without stroke regarding the ipsilesional and contralesional lower limbs kinematics, kinetics, muscle activity and their variability during double support phase of gait. Eleven post-stroke and thirteen healthy participants performed 10 gait trials at a self-selected speed while being monitored by an optoelectronic motion capture system, two force plates and an electromyographic system. The following outcomes were evaluated during the double support: the time and the joint position; the external mechanical work on the centre of mass; and the relative electromyographic activity. Both, contralesional/ipsilesional and dominant/non-dominant of participants with and without stroke, respectively, were evaluated during double support phase of gait in trailing or leading positions. The average value of each parameter and the coefficient of variation of the 10 trials were analysed. Post-stroke participants present bilateral decreased mechanical work on the centre of mass and increased variability, decreased contralesional knee and ankle flexion in trailing position, increased ipsilesional knee flexion in leading position and increased variability. Increased relative muscle activity was observed in post-stroke participants with decreased variability. Mechanical work on the centre of mass seems to be the most relevant parameter to identify interlimb coordination impairments in post-stroke subjects.


Assuntos
Músculo Esquelético , Acidente Vascular Cerebral , Humanos , Músculo Esquelético/fisiologia , Marcha/fisiologia , Extremidade Inferior , Tornozelo , Acidente Vascular Cerebral/complicações , Fenômenos Biomecânicos , Caminhada/fisiologia
4.
Sensors (Basel) ; 23(18)2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37765782

RESUMO

The analysis of the external forces of swimming starts has revealed how swimmers propel themselves out of the block, but data should be properly interpreted to fully understand force-generation mechanisms. This study aimed to assess horizontal and vertical forces in the backstroke start based on swimmers' structural and propulsive actions. Firstly, a simulated structural force was estimated by two transient backstroke-start inter-segmental realistic body positions: a maximally tucked position and an extended one (just before the hands-off and the take-off, respectively). Secondly, 10 competitive backstroke swimmers performed four 15 m maximal backstroke starts with the external forces estimated. Thirdly, the simulated structural force was subtracted from raw horizontal and vertical force data, measured between hands-off and take-off instants, resulting in the propulsive forces. The application of the algorithm has evidenced that backstrokers' horizontal and vertical simulated-structural-force components contributed to ~40% of total force during start propulsion (~0.2-0.12 s before the take-off), followed by the propulsive horizontal force increment and a progressive vertical component reduction (~0.05 s) with ~20° take-off angle. Based on these findings, researchers and coaches can better guide swimmers as to the proper mechanical strategies to achieve effectiveness in the backstroke start, and to improve direct transfer of resistance training programs.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37649818

RESUMO

Background: Occlusal splints with sensors help in the bruxism diagnosis and monitoring, by recording the patient's bite force. The aim of this study was to evaluate the accuracy of a pressure sensor when it is covered with different thicknesses of a 3D printing resin (Anycubic 405nm Translucent Green UV Resin, Anycubic, UK). Methods: In this preliminary study, the evaluated sensor (FlexiForce A201 Sensor, Tekscan) was firstly calibrated without any type of cover material, and later tested with 3D printing resin with different thicknesses (1 mm, 1.15 mm, 1.4 mm and 1.6 mm). The load tests were performed by a force tester (MultiTest 2.5 dV, Mecmesin). Results: When the pressure sensor was covered with resin of 1mm and 1.6 mm thick specimens, a higher difference was found between the applied load and the corresponding sensor reading. Conclusion: It was concluded that it is possible to use this type of pressure sensor and that it showed better accuracy with the 1.15 mm and 1.4 mm 3D printing resin covering.

6.
Sensors (Basel) ; 23(11)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37299854

RESUMO

Physical fatigue reduces productivity and quality of work while increasing the risk of injuries and accidents among safety-sensitive professionals. To prevent its adverse effects, researchers are developing automated assessment methods that, despite being highly accurate, require a comprehensive understanding of underlying mechanisms and variables' contributions to determine their real-life applicability. This work aims to evaluate the performance variations of a previously developed four-level physical fatigue model when alternating its inputs to have a comprehensive view of the impact of each physiological variable on the model's functioning. Data from heart rate, breathing rate, core temperature and personal characteristics from 24 firefighters during an incremental running protocol were used to develop the physical fatigue model based on an XGBoosted tree classifier. The model was trained 11 times with different input combinations resulting from alternating four groups of features. Performance measures from each case showed that heart rate is the most relevant signal for estimating physical fatigue. Breathing rate and core temperature enhanced the model when combined with heart rate but showed poor performance individually. Overall, this study highlights the advantage of using more than one physiological measure for improving physical fatigue modelling. The findings can contribute to variables and sensor selection in occupational applications and as the foundation for further field research.


Assuntos
Bombeiros , Humanos , Fadiga , Monitorização Fisiológica , Eficiência , Frequência Cardíaca
7.
Cureus ; 15(2): e35152, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36950005

RESUMO

Isthmic spondylolisthesis is a condition characterized by the subluxation of one vertebral body over the adjacent inferior vertebral body, secondary to a defect in the pars interarticularis. This paper reports two cases of young acrobatic gymnasts who presented with long-term, progressive lumbosciatic pain and lower limb dysesthesia. One gymnast presented with additional neurogenic bladder dysfunction. Diagnostic testing revealed L5-S1 spondylolisthesis due to bilateral isthmic lysis in both gymnasts. Both underwent L4-S2 fixation followed by L5-S1 transdiscal arthrodesis with Rialto sacroiliac fusion system (Medtronic®, Minneapolis, MN, USA). Favorable evolution of neuromotor symptoms was observed after rehabilitation, with less residual neurological impairment in the case of higher-grade spondylolisthesis. This case series aims to emphasize the importance of recognizing this pathology in athletes as well as its correct management. Early surgical intervention can prevent the onset and progression of neurological deficits.

8.
Sensors (Basel) ; 23(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36904730

RESUMO

Reliable biomechanical methods to assess interlimb coordination during the double-support phase in post-stroke subjects are needed for assessing movement dysfunction and related variability. The data obtained could provide a significant contribution for designing rehabilitation programs and for their monitorisation. The present study aimed to determine the minimum number of gait cycles needed to obtain adequate values of repeatability and temporal consistency of lower limb kinematic, kinetic, and electromyographic parameters during the double support of walking in people with and without stroke sequelae. Eleven post-stroke and thirteen healthy participants performed 20 gait trials at self-selected speed in two separate moments with an interval between 72 h and 7 days. The joint position, the external mechanical work on the centre of mass, and the surface electromyographic activity of the tibialis anterior, soleus, gastrocnemius medialis, rectus femoris, vastus medialis, biceps femoris, and gluteus maximus muscles were extracted for analysis. Both the contralesional and ipsilesional and dominant and non-dominant limbs of participants with and without stroke sequelae, respectively, were evaluated either in trailing or leading positions. The intraclass correlation coefficient was used for assessing intra-session and inter-session consistency analysis. For most of the kinematic and the kinetic variables studied in each session, two to three trials were required for both groups, limbs, and positions. The electromyographic variables presented higher variability, requiring, therefore, a number of trials ranging from 2 to >10. Globally, the number of trials required inter-session ranged from 1 to >10 for kinematic, from 1 to 9 for kinetic, and 1 to >10 for electromyographic variables. Thus, for the double support analysis, three gait trials were required in order to assess the kinematic and kinetic variables in cross-sectional studies, while for longitudinal studies, a higher number of trials (>10) were required for kinematic, kinetic, and electromyographic variables.


Assuntos
Extremidade Inferior , Acidente Vascular Cerebral , Humanos , Estudos Transversais , Caminhada/fisiologia , Marcha/fisiologia , Músculo Esquelético/fisiologia , Fenômenos Biomecânicos , Progressão da Doença , Eletromiografia/métodos
9.
Front Immunol ; 13: 801616, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35401549

RESUMO

Delays in diagnosis and treatment of pulmonary tuberculosis (TB) can lead to more severe disease and increased transmission. Contact investigation among household contacts (HHCs) of TB patients is crucial to ensure optimal outcomes. In the context of a prospective cohort study in Palamaner, Southern India, this study attempted to assess the potential of 27 different soluble immune markers to accurately assign HHCs for appropriate treatment. A multiplex bead assay was applied on QuantiFERON (QFT)-nil supernatants collected from 89 HHCs grouped by longitudinal QFT status; M. tuberculosis (Mtb) infected (QFT positive at baseline and follow-up, n = 30), recent QFT converters (QFT-negative at baseline, n = 27) and converted to QFT-positivity within 6 months of exposure (at follow-up, n = 24) and QFT consistent negatives (n = 32). The 29 TB index cases represented Active TB. Active TB cases and HHCs with Mtb infection produced significantly different levels of both pro-inflammatory (IFNγ, IL17, IL8, IP10, MIP-1α, MIP1ß, and VEGF) and anti-inflammatory (IL9 and IL1RA) cytokines. We identified a 4-protein signature (bFGF, IFNγ, IL9, and IP10) that correctly classified HHCs with Mtb infection vs. Active TB with a specificity of 92.6%, suggesting that this 4-protein signature has the potential to assign HHCs for either full-length TB treatment or preventive TB treatment. We further identified a 4-protein signature (bFGF, GCSF, IFNγ, and IL1RA) that differentiated HHCs with Mtb infection from QFT consistent negatives with a specificity of 62.5%, but not satisfactory to safely assign HHCs to no preventive TB treatment. QFT conversion, reflecting new Mtb infection, induced an elevated median concentration in nearly two-thirds (19/27) of the analyzed soluble markers compared to the levels measured at baseline. Validation in other studies is warranted in order to establish the potential of the immune biosignatures for optimized TB case detection and assignment to therapeutic and preventive treatment of Mtb infected individuals.


Assuntos
Tuberculose , Biomarcadores/análise , Citocinas/análise , Humanos , Mycobacterium tuberculosis , Estudos Prospectivos , Teste Tuberculínico , Tuberculose/diagnóstico , Tuberculose/tratamento farmacológico , Tuberculose/prevenção & controle
10.
Sensors (Basel) ; 22(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35271155

RESUMO

Objective: To identify and summarize biomechanical assessment approaches in interlimb coordination on poststroke gait. Introduction: Interlimb coordination involves complex neurophysiological mechanisms that can be expressed through the biomechanical output. The deepening of this concept would have a significant contribution in gait rehabilitation in patients with an asymmetric neurological impairment as poststroke adults. Inclusion criteria: Poststroke adults (>19 years old), with assessment of interlimb coordination during gait, in an open context, according to the Population, Concept, Context framework. Methods: A literature search was performed in PubMed, Web of Science™, Scopus, and gray literature in Google Scholar™, according to the PRISMA-ScR recommendations. Studies written in Portuguese or English language and published between database inception and 14 November 2021 were included. Qualitative studies, conference proceedings, letters, and editorials were excluded. The main conceptual categories were "author/year", "study design", "participant's characteristics", "walking conditions", "instruments" and "outcomes". Results: The search identified 827 potentially relevant studies, with a remaining seven fulfilling the established criteria. Interlimb coordination was assessed during walking in treadmill (n = 3), overground (n = 3) and both (n = 1). The instruments used monitored electromyography (n = 2), kinetics (n = 2), and kinematics (n = 4) to assess spatiotemporal parameters (n = 4), joint kinematics (n = 2), anteroposterior ground reaction forces (n = 2), and electromyography root mean square (n = 2) outcomes. These outcomes were mostly used to analyze symmetry indices or ratios, to calculate propulsive impulse and external mechanical power produced on the CoM, as well as antagonist coactivation. Conclusions: Assessment of interlimb coordination during gait is important for consideration of natural auto-selected overground walking, using kinematic, kinetic, and EMG instruments. These allow for the collection of the main biomechanical outcomes that could contribute to improve better knowledge of interlimb coordination assessment in poststroke patients.


Assuntos
Marcha , Caminhada , Adulto , Fenômenos Biomecânicos , Teste de Esforço , Marcha/fisiologia , Humanos , Cinética , Caminhada/fisiologia , Adulto Jovem
11.
Sports Biomech ; 21(10): 1303-1311, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32727291

RESUMO

The paddling stroke rate (SR) is one of the key determinants of flat water kayak performance. The aim of this study was to analyse the way in which the kayak paddler changes the duration of the water and aerial phases due to the increase in stroke rate. Ten elite kayak paddlers (five males and five females) were analysed performing 200 m on-water trials in an individual kayak (K1), at four different stroke rates (60, 80, 100 strokes per minute and race pace). The duration of the water and aerial phases, SR and impulse were computed based on the data collected using the FPaddle system. Results corroborate the importance of reaching higher SR to increase kayak velocity (r = 0.904, p < 0.001). Both water and aerial phase durations correlated negatively with SR (r = -0.929, p < 0.001; R = -0.909, p < 0.001, respectively). However, with the first, the correlation was linear (r2 = 0.883), and for the second, the trend of relationship was curvilinear (r2 = 0.893). Due to differences in correlation, the results suggest that at high SR (above 120 strokes per minute) to continue increasing SR it will be more productive to reduce the duration of the water phase.


Assuntos
Esportes , Esportes Aquáticos , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Navios , Água
12.
Ergonomics ; 65(9): 1194-1201, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34930095

RESUMO

The aim of this study was to investigate if increased load carriage, in male military personnel, can affect the lower limbs kinematics. Twelve male military volunteers from the Portuguese Army were recruited and evaluated in an unloaded and loaded gait condition. Linear kinematics and lower limbs joint angle at heel strike, midstance and toe off were calculated. The stance, swing and double support times were found to be different between load conditions (p < 0.05). There was an interaction between load and limb (p < 0.05) for joint angles, during midstance, with limbs performing different movements in the frontal plane during loaded gait. Load increase had a different effect on the right knee, with a reduction in the abduction (valgus). This study may be beneficial in offering suggestion to improve the performance of gait with load and in an attempt to help prevent possible injuries. Practitioner summary: Increased load can affect lower limbs of male soldiers at the pelvic, hip and knee angles on the frontal plane, which can alter the joint force distribution. While these alterations may indicate protective mechanics, load management procedures should be implemented along with gait monitoring to avoid negative effects in performance.


Assuntos
Militares , Fenômenos Biomecânicos , Marcha , Humanos , Articulação do Joelho , Extremidade Inferior , Masculino , Suporte de Carga
13.
Sensors (Basel) ; 23(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36616791

RESUMO

Physical fatigue is a serious threat to the health and safety of firefighters. Its effects include decreased cognitive abilities and a heightened risk of accidents. Subjective scales and, recently, on-body sensors have been used to monitor physical fatigue among firefighters and safety-sensitive professionals. Considering the capabilities (e.g., noninvasiveness and continuous monitoring) and limitations (e.g., assessed fatiguing tasks and models validation procedures) of current approaches, this study aimed to develop a physical fatigue prediction model combining cardiorespiratory and thermoregulatory measures and machine learning algorithms within a firefighters' sample. Sensory data from heart rate, breathing rate and core temperature were recorded from 24 participants during an incremental running protocol. Various supervised machine learning algorithms were examined using 21 features extracted from the physiological variables and participants' characteristics to estimate four physical fatigue conditions: low, moderate, heavy and severe. Results showed that the XGBoosted Trees algorithm achieved the best outcomes with an average accuracy of 82% and accuracies of 93% and 86% for recognising the low and severe levels. Furthermore, this study evaluated different methods to assess the models' performance, concluding that the group cross-validation method presents the most practical results. Overall, this study highlights the advantages of using multiple physiological measures for enhancing physical fatigue modelling. It proposes a promising health and safety management tool and lays the foundation for future studies in field conditions.


Assuntos
Bombeiros , Humanos , Exercício Físico , Fadiga , Aprendizado de Máquina , Frequência Cardíaca/fisiologia
14.
Sensors (Basel) ; 23(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36616930

RESUMO

Lock-in thermal tests (LTTs) are one of the best ways to detect defects in composite materials. The parameter that most affects their performance is the cycle period of the stimulation wave. Its influence on the amplitude-phase results was determined by performing various numeric simulations and laboratory tests. The laboratory tests were used to infer part of the simulation parameters, namely the input and output heat, corresponding to the stimulation and natural convection. The simulations and the analysis of their results focus on the heat flow inside the sample and the manner they change for different geometries. This was performed for poly(methyl methacrylate (PMMA) and carbon fiber-reinforced polymers (CFRPs). The simulation of these materials was also used to create prediction surfaces and equations. These predict the amplitude and phase for a sample with a thickness l and a cycle period. These new findings were validated with new laboratory tests and two new samples. These validated the prediction surfaces and equations and can now be used as a reference for future works and industrial applications.

15.
Front Immunol ; 13: 1051963, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36713386

RESUMO

A large proportion of the global tuberculosis (TB) burden is asymptomatic and not detectable by symptom-based screening, driving the TB epidemic through continued M. tuberculosis transmission. Currently, no validated tools exist to diagnose incipient and subclinical TB. Nested within a large prospective study in household contacts of pulmonary TB cases in Southern India, we assessed 35 incipient TB and 12 subclinical TB cases, along with corresponding household active TB cases (n=11), and household controls (n=39) using high throughput methods for transcriptional and protein profiling. We split the data into training and test sets and applied a support vector machine classifier followed by a Lasso regression model to identify signatures. The Lasso regression model identified an 11-gene signature (ABLIM2, C20orf197, CTC-543D15.3, CTD-2503O16.3, HLADRB3, METRNL, RAB11B-AS1, RP4-614C10.2, RNA5SP345, RSU1P1, and UACA) that distinguished subclinical TB from incipient TB with a very good discriminatory power by AUCs in both training and test sets. Further, we identified an 8-protein signature comprising b-FGF, IFNγ, IL1RA, IL7, IL12p70, IL13, PDGF-BB, and VEGF that differentiated subclinical TB from incipient TB with good and moderate discriminatory power by AUCs in the training and test sets, respectively. The identified 11-gene signature discriminated well between the distinct stages of the TB disease spectrum, with very good discriminatory power, suggesting it could be useful for predicting TB progression in household contacts. However, the high discriminatory power could partly be due to over-fitting, and validation in other studies is warranted to confirm the potential of the immune biosignatures for identifying subclinical TB.


Assuntos
Mycobacterium tuberculosis , Tuberculose Pulmonar , Tuberculose , Humanos , Estudos Prospectivos , Tuberculose/diagnóstico , Tuberculose/epidemiologia , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/epidemiologia , Mycobacterium tuberculosis/genética , Índia/epidemiologia
16.
J Clin Exp Dent ; 13(11): e1124-e1130, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34824699

RESUMO

BACKGROUND: In orthodontic treatment, the combination of an activator with a headgear is commonly used in treatment of the hyperdivergent Class II malocclusion. However, the distribution of stresses transmitted to the maxilla by these appliances has been little studied. This study aimed to compare the biomechanical effects of stresses transmitted to the maxilla and teeth by a Teuscher activator (TA) for different lines of action of extraoral force, using finite element analysis. MATERIAL AND METHODS: A tridimensional finite element model of the maxilla and teeth was created based on the true geometry of a human skull. The (TA) and the face bow were designed in 3D computer-aided design and fixed in the maxilla model. To study the effects of mechanical stress transmitted to the maxilla in the treatment of hyperdivergent Class II malocclusion with (TA) combined with extraoral forces, five different finite element models were used, considering the centers of resistance of the maxilla and dentition. RESULTS: The results showed that stresses increased progressively when the force line of action moved in posteroanterior direction. Von Mises equivalent stress was lower in Model 1 (0°) than in Model 5 (60°). In Models 1 (0°) and 2 (15°), molars suffered greater distal displacement and incisors showed extrusion. In Model 3 (30°), the force line of action promoted a distal displacement of molars and incisors. In Models 4 (45°) and 5 (60°), the whole maxillary anterior sector showed counterclockwise displacement. CONCLUSIONS: Different force lines of action influence the intensity and distribution of orthodontic and orthopedic forces in the maxilla. The extraoral force's line of action used in Model 3 (30°) is the most compatible with the objectives of the hyperdivergent Class II malocclusion treatment in growing patients. Key words:Class II, Headgear, Early treatment, FEA.

17.
Sensors (Basel) ; 21(21)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34770556

RESUMO

The emergence of physiological monitoring technologies has produced exceptional opportunities for real-time collection and analysis of workers' physiological information. To benefit from these safety and health prognostic opportunities, research efforts have explored the applicability of these devices to control workers' wellbeing levels during occupational activities. A systematic review is proposed to summarise up-to-date progress in applying physiological monitoring systems for occupational groups. Adhering with the PRISMA Statement, five databases were searched from 2014 to 2021, and 12 keywords were combined, concluding with the selection of 38 articles. Sources of risk of bias were assessed regarding randomisation procedures, selective outcome reporting and generalisability of results. Assessment procedures involving non-invasive methods applied with health and safety-related goals were filtered. Working-age participants from homogeneous occupational groups were selected, with these groups primarily including firefighters and construction workers. Research objectives were mainly directed to assess heat stress and physiological workload demands. Heart rate related variables, thermal responses and motion tracking through accelerometry were the most common approaches. Overall, wearable sensors proved to be valid tools for assessing physiological status in working environments. Future research should focus on conducting sensor fusion assessments, engaging wearables in real-time evaluation methods and giving continuous feedback to workers and practitioners.


Assuntos
Transtornos de Estresse por Calor , Acelerometria , Frequência Cardíaca , Humanos , Monitorização Fisiológica , Local de Trabalho
18.
Work ; 70(2): 645-655, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34657845

RESUMO

BACKGROUND: Environmental temperatures in the fresh food industry vary from 0°C to 10°C, and go below -20°C for the frozen food industry, representing risk for the health and safety of workers involved. OBJECTIVE: The aim of this work was to evaluate the cold thermal stress risks for workers working in a frozen food industry. METHODS: A total of 27 acclimatized workers (13 male and 14 female) participated in a study which was conducted during 11 working days. The thermal sensation questionnaire and the cold work health questionnaire (CWHQ) were applied to all participants. Additionally, 4 workers were chosen to be fully monitored with a thermometer telemetry capsule for measuring the intra-abdominal temperature and 8 skin temperature sensors. RESULTS: The lowest recorded hand temperature was 14.09°C, lowest forehead 18.55°C, mean skin temperature had variations of 1.10 to 3.20°C along the working period. Highest and most frequent fluctuations were found in the hand and forehead skin temperatures, small changes were found in mean skin temperature. CONCLUSIONS: Answers to the CWHQ increase concern on clinical forms of "a frigore", and in two cases the mean body temperature decreased below 35.0°C, which is defined in the current literature as a mild form of hypothermia.


Assuntos
Indústria de Processamento de Alimentos , Temperatura Cutânea , Temperatura Baixa , Feminino , Mãos , Humanos , Masculino , Sensação Térmica
19.
Artigo em Inglês | MEDLINE | ID: mdl-34639718

RESUMO

The accurate prediction of energy requirements for healthy individuals has many useful applications. The occupational perspective has also been proven to be of great utility for improving workers' ergonomics, safety, and health. This work proposes a statistical regression model based on actigraphy and personal characteristics to estimate energy expenditure and cross-validate the results with reference standardized methods. The model was developed by hierarchical mixed-effects regression modeling based on the multitask protocol data. Measurements combined actigraphy, indirect calorimetry, and other personal and lifestyle information from healthy individuals (n = 50) within the age of 29.8 ± 5 years old. Results showed a significant influence of the variables related to movements, heart rate and anthropometric variables of body composition for energy expenditure estimation. Overall, the proposed model showed good agreement with energy expenditure measured by indirect calorimetry and evidenced a better performance than the methods presented in the international guidelines for metabolic rate assessment proving to be a reliable alternative to normative guidelines. Furthermore, a statistically significant relationship was found between daily activity and energy expenditure, which raised the possibility of further studies including other variables, namely those related to the subject's lifestyle.


Assuntos
Actigrafia , Metabolismo Energético , Adulto , Composição Corporal , Calorimetria Indireta , Frequência Cardíaca , Humanos , Adulto Jovem
20.
Artigo em Inglês | MEDLINE | ID: mdl-34444564

RESUMO

During operational activities, military personnel face extremely demanding circumstances, which when combined lead to severe fatigue, influencing both their well-being and performance. Physical exertion is the main condition leading to fatigue, and its continuous tracking would help prevent its effects. This review aimed to investigate the up-to-date progress on non-invasive physiological monitoring to evaluate situations of physical exertion as a pre-condition to fatigue in military populations, and determine the potential associations between physiological responses and fatigue, which can later result in decision-making indicators to prevent health-related consequences. Adhering to the PRISMA Statement, four databases (Scopus, Science Direct, Web of Science and PubMed) were used for a literature search based on combinations of keywords. The eligibility criteria focused on studies monitoring physiological variables through non-invasive objective measurements, with these measurements being developed in military field, combat, or training conditions. The review process led to the inclusion of 20 studies. The findings established the importance of multivariable assessments in a real-life context to accurately characterise the effects of military practices. A tendency for examining heart rate variables, thermal responses, and actigraphy measurements was also identified. The objectives and experimental protocols were diverse, but the effectiveness of non-invasive measurements in identifying the most fatigue-inducing periods was demonstrated. Nevertheless, no assessment system for standardised application was presented. Future work may include the development of assessment methods to translate physiological recordings into actionable information in real-time and mitigate the effects of fatigue on soldiers' performance accurately.


Assuntos
Militares , Fadiga , Humanos , Monitorização Fisiológica , Esforço Físico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...